173.43 zł tax incl.
Grid for Rilling refrigeration cabinets from the 650 series
Refrigerated cabinet GN 2/1, double-door, forced air circulation, automatic. defrosting and hot gas condensate evaporation, adjustable with digital display
Security policy
Delivery terms
Return policy
Refrigerated cabinet GN 2/1, double-door, forced air circulation, automatic. defrosting and hot gas condensate evaporation, adjustable with digital display. Central cooling with condensate drain. Hygienic interior with rounded edges and an embossed floor. Evaporator located outside the refrigerator compartment. The aggregate in the form of a monoblock located on the top of the device.
Dimensions: | 1390x810x2020 mm (LxDxH) |
Electric power (own cool): | 380W / 230V |
Electric power (central cooling): | 180W / 230V |
Refrigerant: | R290 |
Capacity: | 1400 L |
Cooling capacity: | 550W evaporation temp. -10 ° C max. ambient temperature + 40 ° C |
Temperature: | ° C -2 / +12 top |
Energy consumption: | 4.4 kWh / 24h |
Accessories: | 6 GN 2/1 grates, 6 pairs of guides, Locked (closed with a key) |
Download
Rilling wymiary dla szaf linii 1300
Download (259.1KB)Grid for Rilling refrigeration cabinets from the 650 series
A pair of guides for Rilling refrigeration cabinets from the 650 series.
Refrigerated cabinet GN 2/1, 2-temperature version + / +, with forced air circulation, with an automatic unit. defrosting and evaporation of condensate with hot gas, with regulation with digital display - each chamber has a separate controller. Central cooling with condensate drain.
Grid for Rilling refrigeration cabinets from the 650 series
Grid for Rilling refrigerated and freezer cabinets. Line 410.
Cooled refrigerator with glass door, forced air circulation, automatic. defrosting and condensate evaporation, adjustable with digital display. Central cooling with hot gas condensate drain. Hygienically made interior with rounded
Drive-in refrigeration cabinet GN 2/1 with forced air circulation, with an automatic unit. hot gas defrost and condensate evaporation
Refrigerated cabinet with forced air circulation 530x420 mm grates, with an automatic unit. defrosting and hot gas condensate evaporation, adjustable with digital display. The aggregate in the form of a monoblock located on the top of the device. Central cooling with condensate drain.
Drive-in refrigeration cabinet GN 2/1 with forced air circulation, with an automatic unit. hot gas defrost and condensate evaporation
EN 400x600 refrigerated cabinet with forced air circulation, with automatic unit. defrosting and hot gas condensate evaporation, adjustable with digital display. Central cooling with condensate drain. Hygienic interior with rounded edges and an embossed floor. Evaporator located outside the refrigerator compartment. The aggregate in the form of a monoblock located on the top of the device.
Refrigerated cabinet GN 2/1, double-door, forced air circulation, automatic. defrosting and hot gas condensate evaporation, adjustable with digital display. Central cooling with condensate drain. Hygienic interior with rounded edges
Refrigerated cabinet GN 2/1 with forced air circulation, with an automatic unit. defrosting and hot gas condensate evaporation, adjustable with digital display. Central cooling with condensate drain. Hygienic interior with rounded edges and an embossed floor. Evaporator located outside the refrigerator compartment. The aggregate in the form of a monoblock located on the top of the device.
A refrigerated cabinet with a capacity of 88 liters for individual use, separately switchable LED lighting and double-glazed door.
Cooled refrigerator with glass door, forced air circulation, automatic. defrosting and condensate evaporation, adjustable with digital display. Central cooling with hot gas condensate drain. Hygienically made interior with rounded
Refrigerated cabinet GN 2/1 with forced air circulation, automatic. defrosting and hot gas condensate evaporation, adjustable with digital display. Stainless steel interior. The aggregate in the form of a monoblock located on the top of the device. Central cooling with condensate drain.